: This study investigates the impact of monitoring infrastructure characteristics (specifically sensor penetration and measurement accuracy) on the effectiveness of voltage regulation and congestion management within distribution networks. As distribution system operators transition toward active management, the integration of Distributed renewable Generation (DG) and demand response introduces significant physical and cyber-physical uncertainties. To address these challenges, a smart grid service framework has been employed to optimize flexibility resources from aggregated users and DG inverters through a genetic algorithm. The framework was tested on the IEEE European Low Voltage Test Feeder across various scenarios defined by distributed monitoring systems' penetration and their measurement accuracy. Results show that sensor penetration has a dominant impact: increasing monitoring coverage from 0% to 100% raises the percentage of cases with fewer than one residual congestion from 46.2% to 91.9% (sensors with an accuracy class of 2%), reaching 97.9% with an accuracy class of 0.5%, while voltage violations are eliminated under full monitoring. These findings suggest that widespread sensor deployment, with a suitable measurement accuracy, is a fundamental prerequisite for reliable and efficient smart grid operation.

Uncertainty Effects on Smart Grid Services for Low-Voltage Distribution Networks

Carere, Federico
;
2026-01-01

Abstract

: This study investigates the impact of monitoring infrastructure characteristics (specifically sensor penetration and measurement accuracy) on the effectiveness of voltage regulation and congestion management within distribution networks. As distribution system operators transition toward active management, the integration of Distributed renewable Generation (DG) and demand response introduces significant physical and cyber-physical uncertainties. To address these challenges, a smart grid service framework has been employed to optimize flexibility resources from aggregated users and DG inverters through a genetic algorithm. The framework was tested on the IEEE European Low Voltage Test Feeder across various scenarios defined by distributed monitoring systems' penetration and their measurement accuracy. Results show that sensor penetration has a dominant impact: increasing monitoring coverage from 0% to 100% raises the percentage of cases with fewer than one residual congestion from 46.2% to 91.9% (sensors with an accuracy class of 2%), reaching 97.9% with an accuracy class of 0.5%, while voltage violations are eliminated under full monitoring. These findings suggest that widespread sensor deployment, with a suitable measurement accuracy, is a fundamental prerequisite for reliable and efficient smart grid operation.
2026
distributed energy resources
genetic algorithms
measurement uncertainty
sensor penetration
smart grids
voltage regulation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12607/79406
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
social impact